R404A Refrigerant Gas

R404A is a near-azeotropic A1 HFC blend historically used in low- and medium-temperature commercial and industrial refrigeration.

It has zero ODP but a high 100-year GWP of 3,922, so its modern role is mainly legacy-system service and application-specific transition rather than new long-term equipment platforms.

RefrigerantR404A
CompositionRefrigerant Blend
ASHRAE Safety ClassA1
Typical ApplicationsCommercial Refrigeration & Cold Storage

Available in multiple small-cylinder and larger-volume supply formats. Confirm current specification, packaging and destination requirements before ordering.

Category:

Description

Product Overview

R404A Refrigerant Gas

R404A is an HFC refrigerant blend containing approximately 44% R125, 52% R143a and 4% R134a by mass. It is classified A1 and behaves near-azeotropically with very small temperature glide.

R404A became a standard refrigerant for low- and medium-temperature commercial and industrial refrigeration, including freezer racks, cold rooms, ice machines and transport refrigeration.

Its major modern limitation is climate impact: the U.S. EPA Technology Transitions reference value is GWP 3,922. As a result, many new-equipment applications have moved to lower-GWP refrigerants while a large installed service base remains.

For detailed technical and regulatory context, see the R404A refrigerant profile and R404A replacement guide.

At a Glance

Key R404A Refrigerant Properties

Key R404A properties relevant to refrigeration service, sourcing and transition planning.

Refrigerant Number
R404A
HFC blend
Composition
R125 / R143a / R134a
44 / 52 / 4 mass %
ASHRAE Safety Class
A1
Lower toxicity / no flame propagation
100-Year GWP
3,922
EPA Technology Transitions reference
ODP
0
No ozone depletion
Transport Class
Class 2.2
Non-flammable gas transport class
Technical Data

R404A Technical Specifications

R404A is a near-azeotropic blend. The current EPA GWP differs slightly from some older product literature, so the reference basis should always be stated.

Refrigerant Designation R404A
Nominal Composition R125 / R143a / R134a = 44 / 52 / 4 mass %
Refrigerant Type Near-azeotropic HFC blend
Average Molecular Weight ≈ 97.6 g/mol
Normal Boiling Reference ≈ -46.6°C
Critical Temperature ≈ 72.5°C
Critical Pressure ≈ 37.8 bar
Ozone Depletion Potential (ODP) 0
100-Year Global Warming Potential 3,922 — EPA Technology Transitions reference
ASHRAE Safety Class A1
Transport Hazard Class Class 2.2
Technical data note

Reference values are provided for product identification and research. For system design, charging, service and compliance, use the current supplier P-T data, SDS, certificate of analysis where applicable, OEM documentation and the regulations governing the project.

Applications

Typical R404A Applications

R404A is strongly associated with the legacy low-temperature refrigeration installed base. Current acceptability for new or retrofit equipment depends on the exact end use and jurisdiction.

Supermarket Freezer Systems

R404A was widely used in low-temperature supermarket racks, display cases and freezer circuits.

Cold Rooms & Walk-In Freezers

Food service, distribution and cold-storage facilities have a large installed base of R404A equipment.

Commercial Refrigeration

Condensing units and other medium- and low-temperature refrigeration equipment have historically used R404A.

Transport Refrigeration

Road, marine and reefer equipment historically used R404A, although new product rules increasingly favor alternatives.

Ice Machines

R404A remains present in installed commercial ice-making and specialty low-temperature equipment.

Industrial Refrigeration

Selected direct-expansion industrial refrigeration systems use R404A within their approved operating envelope.

Explore current system pathways in the Commercial Refrigeration and Cold Storage Refrigerants guides.

Safety & Handling

R404A Safety and Handling Considerations

R404A is A1, so flammability is not its defining safety issue. Pressure, cold injury, oxygen displacement, hot-work decomposition and very high climate impact of leakage still matter.

Leak Prevention

With a GWP of 3,922, reducing chronic leakage has major environmental and operating-cost value.

Pressure & Cold Exposure

Use appropriate PPE and service equipment rated for R404A operating and recovery pressures.

Blend Handling

R404A has very small glide but remains a blend. Follow refrigerant-specific charging, recovery and contamination-control procedures.

Do not mix R404A with R507A or retrofit blends

R404A, R507A and lower-GWP transition refrigerants may serve similar applications, but they are not the same composition. Mixing refrigerants can compromise performance, reclamation quality and system identification.

Supply Specification

R404A Product Specification & Documentation

The blend composition should match the recognized R404A formulation; final batch quality and packaging should be confirmed from current order documentation.

Refrigerant Identity R404A
Nominal Composition R125 44% / R143a 52% / R134a 4% by mass
Supplied Form Liquefied compressed refrigerant blend
Transport Classification Class 2.2
Batch Documentation Confirm current specification, COA where supplied and SDS with the order
Packaging & Supply

R404A Refrigerant Packaging Options

The supplied product information lists multiple R404A sizes for distribution, service and large-volume orders.

Packaging Type Reference Size Supply Note
Small Container 650 g Small-volume supply
Cylinder 2.7 kg / 5.4 kg / 10.9 kg Service, wholesale and distributor supply
Large Supply Reference 650 kg format Large-volume supply; final container configuration must be confirmed
Packaging availability

Packaging, filling weight, valve configuration, cylinder type, minimum order quantity and bulk availability may vary by destination and order requirement. Confirm the final supply configuration before ordering.

Market & Transition Context

R404A Is Now Primarily a Legacy-Service Refrigerant

R404A delivered reliable low-temperature refrigeration performance, but its very high GWP made it an early target for HFC transition policy.

Existing systems can still create legitimate service and refrigerant-management demand, while new equipment increasingly moves to lower-GWP A1, A2L or natural-refrigerant architectures depending on application.

For retrofit and replacement research, use the R404A Replacement Guide and verify the exact system against OEM and regulatory requirements.

  • Maintain: service existing approved equipment where permitted.
  • Retrofit: evaluate refrigerants such as R448A or R449A only where the specific system and procedure support them.
  • Replace equipment: consider current low-GWP platforms when major system replacement is economically justified.
A lower-GWP refrigerant is not automatically a drop-in

R448A, R449A, R452A, R454C, R290, R744 and other alternatives have different composition, glide, safety or system requirements. Selection must be application- and equipment-specific.

FAQ

R404A Refrigerant Frequently Asked Questions

What is R404A refrigerant?

R404A is a near-azeotropic HFC blend containing 44% R125, 52% R143a and 4% R134a by mass.

What is the GWP of R404A?

The U.S. EPA Technology Transitions reference table lists R404A at a 100-year GWP of 3,922.

Is R404A flammable?

R404A is classified A1, meaning lower toxicity and no flame propagation under the refrigerant safety classification framework.

Where is R404A used?

It is strongly associated with legacy low- and medium-temperature commercial refrigeration, cold rooms, supermarket freezers, ice machines and transport refrigeration.

What packaging is available for R404A?

The supplied product list includes 650 g, 2.7 kg, 5.4 kg and 10.9 kg formats plus a reference 650 kg large-volume format.

Is R507A the same as R404A?

No. Their applications overlap, but R507A is a 50/50 R125/R143a azeotropic blend while R404A also contains R134a and has a different GWP.

Can R448A replace R404A directly?

Do not assume a universal drop-in. Retrofit suitability depends on compressor approval, expansion device, glide, discharge temperature, lubricant and system condition.

Is R404A still relevant?

Yes for the installed service base, but it is generally a legacy high-GWP refrigerant rather than a preferred new-system platform.

Product and compliance notice

Product information on Refrigerants.net is provided for product identification, comparison and B2B purchasing research. Final refrigerant specification, packaging, availability, transport requirements, permitted use and equipment compatibility should be confirmed against current product documentation, SDS, OEM requirements and applicable regulations before purchase or use.

Additional information

Application

Cold Storage, Commercial Refrigeration, Transport Refrigeration

Composition Type

Refrigerant Blend

ASHRAE Safety Class

A1

Package Size

10.9 kg, 2.7 kg, 5.4 kg, 650 g, 650 kg

Packaging Type

Disposable Cylinder, ISO Tank / Bulk, Refillable Cylinder, Small Can

Refrigerant Number

R404A

Transport Hazard Class

Class 2.2

Reviews

There are no reviews yet.


Be the first to review “R404A Refrigerant Gas”

Reviews

There are no reviews yet.


Be the first to review “R404A Refrigerant Gas”