R507A Refrigerant Gas

R507A is an azeotropic HFC refrigerant blend containing 50% R125 and 50% R143a by mass, historically used in low- and medium-temperature refrigeration.

It is closely associated with commercial and industrial refrigeration installed bases and has an A1 safety classification, but its high GWP makes current use strongly application- and regulation-dependent.

RefrigerantR507A
CompositionRefrigerant Blend
ASHRAE Safety ClassA1
Typical ApplicationsCommercial Refrigeration & Cold Storage

Available in cylinder and larger-volume supply formats. Confirm current packaging, batch specification and destination requirements for each order.

Category:

Description

Product Overview

R507A Refrigerant Gas

R507A is an azeotropic HFC blend of R125 and R143a in a nominal 50/50 mass ratio. It has zero ozone depletion potential and an A1 safety classification.

The refrigerant became established in low- and medium-temperature commercial and industrial refrigeration, including applications with operating characteristics similar to those historically served by R404A.

The U.S. EPA Technology Transitions reference table lists R507A at a 100-year GWP of 3,985. That high climate impact has shifted the market toward lower-GWP alternatives for many new systems while R507A remains relevant to installed equipment and service supply.

For technical context, see the R507A refrigerant profile and the R404A replacement guide for related low-temperature transition research.

At a Glance

Key R507A Refrigerant Properties

Core reference data for identifying R507A and screening commercial refrigeration applications.

Refrigerant Number
R507A
50/50 R125 / R143a blend
Refrigerant Type
Azeotropic Blend
HFC refrigerant
ASHRAE Safety Class
A1
Lower toxicity / no flame propagation
100-Year GWP
3,985
U.S. EPA Technology Transitions
ODP
0
No ozone depletion
Transport Class
Class 2.2
Non-flammable gas transport class
Technical Data

R507A Technical Specifications

The table below uses established composition, safety and climate-reference data for R507A without assuming equipment compatibility.

Refrigerant Designation R507A
Nominal Composition R125 / R143a = 50 / 50 mass %
Refrigerant Type Azeotropic HFC blend
Ozone Depletion Potential (ODP) 0
100-Year Global Warming Potential 3,985 — U.S. EPA Technology Transitions reference
ASHRAE Safety Class A1
Transport Hazard Class Class 2.2
Technical data note

Use the exact supplier pressure-temperature data, SDS and OEM documentation for charging, service and engineering work. Similar application history does not establish interchangeability with R404A or any other refrigerant.

Applications

Typical R507A Applications

R507A is primarily associated with low- and medium-temperature refrigeration. The examples below describe recognized use contexts, not blanket approval for every system.

Commercial Refrigeration

R507A has been used in low- and medium-temperature commercial refrigeration systems designed and approved for the blend.

Cold Storage

Cold rooms, freezer systems and related low-temperature installations form part of the established R507A installed base.

Industrial Refrigeration

Selected industrial direct-expansion refrigeration systems use R507A where the compressor, lubricant and components are specified for it.

See our Commercial Refrigeration and Cold Storage Refrigerants guides for application-level selection context.

Safety & Handling

R507A Safety and Handling Considerations

R507A is A1, but safe service still requires attention to pressure, oxygen displacement, cold-contact injury and recovery procedures.

Pressurized Refrigerant

Use cylinders, hoses, recovery equipment and gauges rated for R507A and the actual system pressure.

Cold Contact

Liquid refrigerant can cause frostbite during rapid release. Use appropriate eye, hand and skin protection.

Recovery & Ventilation

Recover refrigerant during service and equipment retirement, and provide adequate ventilation where a significant release could occur.

Do not infer compatibility from R404A similarity

R507A and R404A have overlapping historical applications but different compositions and climate metrics. Confirm OEM approval, lubricant, compressor operating envelope and service procedure before any refrigerant change.

Supply Specification

R507A Product Specification & Documentation

Supply specifications should be confirmed from current batch documentation and order-specific product information.

Refrigerant Identity R507A
Nominal Composition 50% R125 / 50% R143a by mass
Supplied Form Liquefied compressed refrigerant blend
Batch Documentation Current specification / COA available according to order requirements
Packaging & Supply

R507A Refrigerant Packaging Options

The supplied product information includes standard cylinder and larger-volume R507A supply references.

Packaging Type Reference Size Supply Note
Cylinder 11.3 kg Service, wholesale and distributor supply
Large-Volume Supply 690 kg reference Confirm cylinder / bulk configuration and logistics before ordering
Packaging availability

Packaging type, filling weight, valve configuration and large-volume supply method may vary by market and shipment. Confirm the exact order configuration before purchase.

Market & Transition Context

R507A Is Primarily an Installed-Base and Transition Refrigerant

R507A delivered zero-ODP refrigeration performance for low-temperature applications, but its high GWP now limits its long-term role in many new-equipment pathways.

Existing R507A equipment may continue to create service demand, while new and retrofit projects increasingly evaluate lower-GWP refrigerants or different system architectures according to the application.

  • Installed equipment: maintain only with the refrigerant and service practices approved for the system.
  • Retrofit research: compare alternatives such as R448A, R449A and other application-approved routes rather than assuming a direct swap.
  • New systems: select refrigerant from the approved equipment platform and current regional regulation.
R507A and R404A are not the same blend

Do not treat overlapping application history as proof that one refrigerant can always replace the other without an OEM-approved procedure.

FAQ

R507A Refrigerant Frequently Asked Questions

What is R507A refrigerant?

R507A is an azeotropic HFC blend containing 50% R125 and 50% R143a by mass.

What is the GWP of R507A?

The U.S. EPA Technology Transitions reference table lists R507A at a 100-year GWP of 3,985.

What is the safety class of R507A?

R507A is classified A1.

What is R507A used for?

It is primarily associated with low- and medium-temperature commercial and industrial refrigeration and cold-storage applications.

Is R507A the same as R404A?

No. They have overlapping refrigeration applications but different blend compositions and GWP values.

Can R507A be replaced with a lower-GWP refrigerant?

Some systems have application-specific retrofit pathways, but the correct choice depends on compressor approval, lubricant, controls, operating temperature and current regulation.

Product and compliance notice

Product information on Refrigerants.net is provided for product identification, comparison and B2B purchasing research. Final refrigerant specification, packaging, availability, transport requirements, permitted use and equipment compatibility should be confirmed against current product documentation, SDS, OEM requirements and applicable regulations before purchase or use.

Additional information

Application

Cold Storage, Commercial Refrigeration

Composition Type

Refrigerant Blend

ASHRAE Safety Class

A1

Package Size

11.3 kg, 690 kg

Packaging Type

Disposable Cylinder, ISO Tank / Bulk, Refillable Cylinder

Refrigerant Number

R507A

Transport Hazard Class

Class 2.2

Reviews

There are no reviews yet.


Be the first to review “R507A Refrigerant Gas”

Reviews

There are no reviews yet.


Be the first to review “R507A Refrigerant Gas”